TSS Portable Hand-held Turbidity, Suspended Solids and Sludge Level System

1 customer review

Compact instrument for analytical determination by continuous measurement mode with integration time setting. Adjustment of up to 5 measuring points, storage of measuring values with name, date and time. Shockproof. Combined multiple beam alternating light method with infrared diode system and beam focusing; wavelength 860 nm. The measurement ranges for turbidity and suspended solids are: 0.001- 9999 FNU and 0.001-400 g/L respectively.

quantity1 RM24.99RM0.00Add to cart
SKU
Categories
Tags

Compact instrument for analytical determination by continuous measurement mode with integration time setting. Adjustment of up to 5 measuring points, storage of measuring values with name, date and time. Shockproof. Combined multiple beam alternating light method with infrared diode system and beam focusing; wavelength 860 nm. The measurement ranges for turbidity and suspended solids are: 0.001- 9999 FNU and 0.001-400 g/L respectively.

Cable Length 10 m (32.8 ft.) cable with marks for distance
Current Input Approx 60 mA
Diameter 40 mm
Dimension
Case L: 450 mm (17.7 in)
Meter (H X W X D): 110 x 230 x 40 mm (4.33 x 9.06 x 1.57 in.)
Probe (Ø X L) 40 mm x 29 cm (1.57 x 11.42 in.)
Display Aplhanumerical display, 4 row of 16 characters
Length 290 mm
Material
Sensor Body : Stainless Steel
Probe : Stainless Steel
Sensor Windows : Sapphire
Measurement Modes Continuos measurement, integration time setting 0 - 1000 seconds
Measuring Principle
Combined multiple beam alternating light method with infrared diode system and beam focusing
Turbidity : 2-channel 90° scattered light measurement in accordance with DIN/EN 27027?ISO 7027
Additional measurement value verification through six-channel multiple-angle measurement
Solids : Modified absorption measurement : six-channel multiple-angle measurement
Measuring Range TSS 0.001 to 400 g/L upper range depending on sample characteristics
Measuring Range Turbidity 0.001 to 9999 FNU
Memory Up to 290 measuring points
Operating Pressure 0 to 10 bar (0 to 145 psi)
Power Automatic shut down after 4 minutes (if no button has been pressed and no permanent measurement is activated)
Precision Suspended Solids < 4 % ± 0.001 g/L , whichever is greater
Precision Turbidity < 3 % or ± 0.02 NTU , whichever is greater
Pressure Range Max. 10 bar
Protection Class Probe IP68 : Control Unit IP 55
Range
TSS 0.001 to 400 g/L
Turbidity 0.001 to 9999 FNU
Relative Humidity 0 - 95 %
Resolution
Suspended Solids : 0.01 at 1 - 9.999 g/L
Suspended Solids : 0.1 at 10 - 99.9 g/L
Suspended Solids : 1 at greaterthan 100 g/L
Resolution Turbidity
0.001 at 0 to 0.999 NTU
0.01 at 1 – 9.99 NTU
0.1 at 10 – 99.9 NTU
1 at greater than 100 NTU
Sensor Cable 10 m
Weight
Probe : 3.5 lbs (1.6 kg)
Meter : 1.2 lbs (0.54 kg)
Width 2 450 mm
John Doe

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Dolores, eveniet, eligendi et nobis neque minus mollitia sit repudiandae ad repellendus recusandae blanditiis praesentium

Mary Jane

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Dolores, eveniet, eligendi et nobis neque minus mollitia sit repudiandae ad repellendus recusandae blanditiis praesentium

Add a review

Related Products

GETAC V110
RM24.99RM0.00
YSI PRODSS
RM24.99RM0.00
GETAC T800
RM0.00
PANASONIC CF-20
RM24.99RM0.00